Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 88
Filter
1.
Annals of Clinical Microbiology ; : 55-60, 2021.
Article in English | WPRIM | ID: wpr-896716

ABSTRACT

Healthcare workers (HCWs) may be at high risk for exposure to the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) because of their frequent contact with patients or the direct handling of respiratory samples. We investigated the seroprevalence of SARS-CoV-2 IgG in HCWs in Seoul compared to those in coronavirus disease (COVID-19) patients and community-based individuals to evaluate the antibody response. A total of 358 samples from 348 individuals (155 HCWs, 7 COVID-19 patients, and 186 community-based individuals) were collected from April to November 2020. SARS-CoV-2 IgG was detected in 1 of 155 HCWs (1 of 46 HCWs with direct contact), 7 of 7 COVID-19 patients, and none of the 186 communitybased individuals (95% CI: 0.6%, 0.1 - 3.6%; 100%, 64.5 - 100%; 0.0%, 0.0 - 2.0%, respectively).The single HCW with a positive result showed 2.32 signal-to-cutoff (S/C) and 2.31 S/C at a 3-week interval. Therefore, it was assumed to be a false positive due to autoantibody or medication. The positive samples from 7 patients had a median of 3.79 S/C (range 1.72 - 6.54). The seroprevalence of SARS-CoV-2 IgG in HCWs was very low. The current infection control standard seems to be effective in protecting HCWs from COVID-19.

2.
Annals of Laboratory Medicine ; : 60-67, 2021.
Article in English | WPRIM | ID: wpr-874136

ABSTRACT

Background@#Neutrophil gelatinase-associated lipocalin (NGAL) is a useful biomarker for acute kidney injury (AKI) prediction. However, studies on whether using both plasma NGAL (PNGAL) and urine NGAL (UNGAL) can improve AKI prediction are limited. We investigated the best approach to predict AKI in high-risk patients when using PNGAL and UNGAL together. @*Methods@#We enrolled 151 AKI suspected patients with one or more AKI risk factors. We assessed the diagnostic performance of PNGAL and UNGAL for predicting AKI according to chronic kidney disease (CKD) status by determining the areas under the receiver operating curve (AuROC). Independent predictors of AKI were assessed using univariate and multivariate logistic regression analyses. @*Results@#In the multivariate logistic regression analysis for all patients (N = 151), Model 2 and 3, including PNGAL (P = 0.012) with initial serum creatinine (S-Cr), showed a better AKI prediction power (R2 = 0.435, both) than Model 0, including S-Cr only (R2 = 0.390). In the non-CKD group (N = 135), the AuROC of PNGAL for AKI prediction was larger than that of UNGAL (0.79 vs 0.66, P = 0.010), whereas in the CKD group (N = 16), the opposite was true (0.94 vs 0.76, P = 0.049). @*Conclusions@#PNGAL may serve as a useful biomarker for AKI prediction in high-risk patients. However, UNGAL predicted AKI better than PNGAL in CKD patients. Our findings provide guidance for selecting appropriate specimens for NGAL testing according to the presence of CKD in AKI high-risk patients.

3.
Annals of Clinical Microbiology ; : 55-60, 2021.
Article in English | WPRIM | ID: wpr-889012

ABSTRACT

Healthcare workers (HCWs) may be at high risk for exposure to the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) because of their frequent contact with patients or the direct handling of respiratory samples. We investigated the seroprevalence of SARS-CoV-2 IgG in HCWs in Seoul compared to those in coronavirus disease (COVID-19) patients and community-based individuals to evaluate the antibody response. A total of 358 samples from 348 individuals (155 HCWs, 7 COVID-19 patients, and 186 community-based individuals) were collected from April to November 2020. SARS-CoV-2 IgG was detected in 1 of 155 HCWs (1 of 46 HCWs with direct contact), 7 of 7 COVID-19 patients, and none of the 186 communitybased individuals (95% CI: 0.6%, 0.1 - 3.6%; 100%, 64.5 - 100%; 0.0%, 0.0 - 2.0%, respectively).The single HCW with a positive result showed 2.32 signal-to-cutoff (S/C) and 2.31 S/C at a 3-week interval. Therefore, it was assumed to be a false positive due to autoantibody or medication. The positive samples from 7 patients had a median of 3.79 S/C (range 1.72 - 6.54). The seroprevalence of SARS-CoV-2 IgG in HCWs was very low. The current infection control standard seems to be effective in protecting HCWs from COVID-19.

4.
Laboratory Medicine Online ; : 250-254, 2020.
Article | WPRIM | ID: wpr-836916

ABSTRACT

Mucormycosis is a fungal infection, which is difficult to treat due to its rapid dissemination and low susceptibility to anti-fungal agents. Peritonitis preceded by gastrointestinal mucormycosis is very rare, and only a few cases have been reported. We present a case of peritonitis and disseminated mucormycosis caused by Mucor circinelloides in an immunocompromised patient. A 59-year-old man, diagnosed with nodal marginal zone B-cell lymphoma, was diagnosed with liver failure due to severe septic shock. A white, woolly cotton-like growth, which was consistent with that of Mucor species, was isolated from ascites and sputum specimens. Targeted DNA sequencing confirmed the isolate as M. circinelloides with 100% identity. Despite anti-fungal treatment, the patient died after four days. This is a rare case of peritonitis and disseminated mucormycosis that was probably preceded by gastrointestinal mucormycosis caused by M. circinelloides, as determined by molecular methods. Accurate and rapid identification of mold using molecular methods might be necessary for early treatment in critical cases, and more cases should be clinically evaluated further.

5.
Annals of Laboratory Medicine ; : 466-473, 2020.
Article | WPRIM | ID: wpr-830420

ABSTRACT

Background@#Kidney failure occurs frequently and is associated with high mortality during sepsis. Proenkephalin (PENK) is an emerging biomarker of kidney function. We explored whether PENK levels could predict severity, organ failure, and mortality in septic patients. @*Methods@#We measured the PENK level in the plasma of 215 septic patients using the sphingotest penKid assay (Sphingotec GmbH, Hennigsdorf, Germany). This was analyzed in terms of sepsis severity, vasopressor use, 30-day mortality, sequential organ failure assessment (SOFA) renal subscore, the Chronic Kidney Disease Epidemiology Collaboration estimated glomerular filtration rate (CKD-EPI eGFR) categories, and renal replacement therapy (RRT) requirement. @*Results@#The PENK levels were significantly higher in patients with septic shock, vasopressor use, and non-survivors than in patients with solitary sepsis, no vasopressor use, and survivors, respectively (P = 0.02, P = 0.007, P < 0.001, respectively). The PENK levels were significantly associated with SOFA renal subscore and CKD-EPI eGFR categories (both P < 0.001). The distribution of lower eGFR ( < 60 mL/min/1.73 m2 ), RRT requirement, SOFA renal subscore, and the number of organ failures differed significantly according to the PENK quartile (P for trend < 0.001 or 0.017). The 30-day mortality rate also differed significantly according to the PENK quartile (P for trend < 0.001). @*Conclusions@#PENK could be an objective and reliable marker to predict severity, organ failure, and 30-day mortality in septic patients.

6.
Annals of Laboratory Medicine ; : 297-305, 2020.
Article in English | WPRIM | ID: wpr-811101

ABSTRACT

BACKGROUND: High-density lipoprotein cholesterol (HDL-C) is a complex mixture of subclasses with heterogeneous atheroprotective activities. We analyzed HDL-C subclass in relation to cardiovascular risk and metabolic syndrome (MetS) in a population with high HDL-C levels.METHODS: A total of 300 Korean individuals with high HDL-C levels (≥2.331 mmol/L) were enrolled following a comprehensive general medical examination including body composition analysis. HDL3-C levels were measured using the HDL3-EX SEIKEN kit (Randox Ltd., Crumlin, UK) and non-HDL3-C levels were calculated by subtracting HDL3-C levels from total HDL-C levels.RESULTS: HDL3-C levels and HDL3-C proportion had a weak positive correlation with low-density lipoprotein cholesterol (LDL-C) and triglycerides (r=0.21, r=0.25; r=0.26, r=0.34, respectively, all P<0.001); in contrast, non-HDL3-C levels had a weak negative correlation with these parameters (r=−0.17 and r=−0.25, respectively, both P<0.005). HDL3-C levels and HDL3-C proportion were significantly higher in the MetS group (N=8) than in the non-MetS group (0.71 vs 0.63 mmol/L, P=0.001; 29.7 vs 25.8%, P=0.001, respectively); these were the only predictors of MetS among the lipid variables (areas under the curves [AUC]=0.84 and 0.83, respectively, both P=0.001).CONCLUSIONS: In populations with high HDL-C levels, HDL-C subclass may provide a greater amount of information on cardiovascular risk and MetS than HDL-C levels alone.

7.
Annals of Laboratory Medicine ; : 97-98, 2020.
Article in English | WPRIM | ID: wpr-762479

ABSTRACT

No abstract available.


Subject(s)
Acute Kidney Injury , Hepcidins , Inflammation , Iron , Lipocalins , Metabolism , Neutrophils
8.
Annals of Laboratory Medicine ; : 72-75, 2020.
Article in English | WPRIM | ID: wpr-762451

ABSTRACT

Accurate detection of BCR-ABL fusion transcripts at and below molecular response (MR) 4 (0.01% International Scale [IS]) is required for disease monitoring in patients with chronic myeloid leukemia (CML). We evaluated the analytical performance of the QXDx BCR-ABL %IS (Bio-Rad, Hercules, CA, USA) droplet digital PCR (ddPCR) assay, which is the first commercially available ddPCR-based in vitro diagnostics product. In precision analysis, the %CV was 9.3% and 3.0%, with mean values of 0.031% IS and 9.4% IS, respectively. The assay was linear in the first order, ranging from 0.032% IS to 20% IS. The manufacturer-claimed limit of blank, limit of detection, and limit of quantification were verified successfully. There was a very strong correlation between the results of the QXDx BCR-ABL %IS ddPCR assay and the ipsogen BCR-ABL1 Mbcr IS-MMR (Qiagen, Hilden, Germany) real-time quantitative PCR assay (r=0.996). In conclusion, the QXDx BCR-ABL %IS ddPCR assay can provide reliable results for CML patients.


Subject(s)
Humans , In Vitro Techniques , Leukemia, Myelogenous, Chronic, BCR-ABL Positive , Limit of Detection , Polymerase Chain Reaction
9.
Annals of Laboratory Medicine ; : 1-2, 2019.
Article in English | WPRIM | ID: wpr-719655

ABSTRACT

No abstract available.


Subject(s)
Flow Cytometry , Microscopy , Urinalysis
11.
The Korean Journal of Internal Medicine ; : 893-901, 2018.
Article in English | WPRIM | ID: wpr-716633

ABSTRACT

BACKGROUND/AIMS: In countries with a higher risk of gastric atrophic gastritis, noninvasive tests are helpful for a more reliable diagnosis of Helicobacter pylori infection. The aim of this study was to evaluate the characteristics of seropositive subjects according to their stool H. pylori antigen test, serum pepsinogen (PG) assay, and endoscopic findings. METHODS: Consecutive subjects who visited Konkuk University Medical Center for upper gastrointestinal endoscopy for a regular check-up were included in a prospective setting if the serum anti-H. pylori immunoglobulin G assay was positive. A H. pylori antigen stool test was measured using a stool H. pylori antigen enzyme-linked immunosorbent assay kit on the same day as a serum PG assay and endoscopy. RESULTS: Of 318 seropositive subjects, 256 (80.5%) showed positive stool test findings. Subjects with a negative stool test result showed lower serum PG I (p < 0.001) and PG II (p < 0.001) levels and higher PG I/II ratio (p < 0.001) than those with a positive stool test. Chronic atrophic gastritis was more common in the positive stool test group than the negative stool test group on endoscopic finding (p = 0.009). A higher serum PG I level (p = 0.001) and a lower serum PG I/II ratio (p = 0.001) were independent risk factors for the presence of H. pylori antigen in stool. CONCLUSIONS: A high serum PG level denotes an ongoing current H. pylori infection with positive stool H. pylori antigen test findings. Seropositive subjects with increased gastric secreting ability tend to have H. pylori in their fecal material as reflected by a positive stool H. pylori antigen test finding.


Subject(s)
Academic Medical Centers , Diagnosis , Endoscopy , Endoscopy, Gastrointestinal , Enzyme-Linked Immunosorbent Assay , Gastritis, Atrophic , Helicobacter pylori , Helicobacter , Immunoglobulin G , Pepsinogen A , Prospective Studies , Risk Factors
12.
Annals of Laboratory Medicine ; : 289-290, 2018.
Article in English | WPRIM | ID: wpr-715667

ABSTRACT

No abstract available.


Subject(s)
Biomarkers , Carrier Proteins , Glycosylation , Liver Cirrhosis , Liver
13.
Annals of Laboratory Medicine ; : 331-337, 2018.
Article in English | WPRIM | ID: wpr-715661

ABSTRACT

BACKGROUND: Liver biopsies have been partially replaced by noninvasive methods for assessing liver fibrosis. We explored the usefulness of four novel biomarkers, enhanced liver fibrosis (ELF), glycosylation isomer of Mac-2 binding protein (M2BPGi), galectin-3, and soluble suppression of tumorigenicity 2 (sST2), in association with liver fibrosis. METHODS: ELF, M2BPGi, galectin-3, and sST2 were assayed in 173 patients with chronic liver diseases. The results were analyzed according to fibrosis grade (F0/1, F2, and F3/4) by transient elastography (TE). RESULTS: ELF, M2BPGi, galectin-3, and sST2 values differed significantly according to TE grade; ELF and M2BPGi values were higher in F2 and F3/4 than in F0/1 (P≤0.001, all), sST2 values were higher in F3/4 than in F0/1 and F2 (P < 0.05), and galectin-3 values were higher in F3/4 than in F0/1 (P=0.0036). ELF and M2BPGi showed good TE fibrosis detection performance (area under the curves [AUC], 0.841 and 0.833 for ≥F2; and 0.837 and 0.808 for ≥F3). The sensitivity and specificity for predicting TE grade F≥2 were 84.1% and 76.7% for ELF and 63.6% and 91.5% for M2BPGi. CONCLUSIONS: This is the first study to compare the liver fibrosis assessment of four novel biomarkers: ELF, M2BPGi, galectin-3, and sST2. The biomarkers varied significantly according to TE grade, and each biomarker showed a different trend. ELF and M2BPGi seem to have comparable good performance for detecting liver fibrosis.


Subject(s)
Humans , Biomarkers , Biopsy , Carrier Proteins , Elasticity Imaging Techniques , Fibrosis , Galectin 3 , Glycosylation , Liver Cirrhosis , Liver Diseases , Liver , Sensitivity and Specificity
14.
Annals of Laboratory Medicine ; : 393-394, 2018.
Article in English | WPRIM | ID: wpr-717063

ABSTRACT

No abstract available.


Subject(s)
Kidney , Lipocalins , Neutrophils
15.
Annals of Laboratory Medicine ; : 204-211, 2018.
Article in English | WPRIM | ID: wpr-714528

ABSTRACT

BACKGROUND: The prognostic utility of cardiac biomarkers, high-sensitivity cardiac troponin I (hs-cTnI) and soluble suppression of tumorigenicity-2 (sST2), in non-cardiac surgery is not well-defined. We evaluated hs-cTnI and sST2 as predictors of 30-day major adverse cardiac events (MACE) in patients admitted to the surgical intensive care unit (SICU) following major non-cardiac surgery. METHODS: hs-cTnI and sST2 concentrations were measured in 175 SICU patients immediately following surgery and for three days postoperatively. The results were analyzed in relation to 30-day MACE and were compared with the revised Goldman cardiac risk index (RCRI) score. RESULTS: Overall, 30-day MACE was observed in 16 (9.1%) patients. hs-cTnI and sST2 concentrations differed significantly between the two groups with and without 30-day MACE (P < 0.05). The maximum concentration of sST2 was an independent predictor of 30-day MACE (odds ratio=1.016, P=0.008). The optimal cut-off values of hs-cTnI and sST2 for predicting 30-day MACE were 53.0 ng/L and 182.5 ng/mL, respectively. A combination of hs-cTnI and sST2 predicted 30-day MACE better than the RCRI score. Moreover, 30-day MACE was observed more frequently with increasing numbers of above-optimal cut-off hs-cTnI and sST2 values (P < 0.0001). Reclassification analyses indicated that the addition of biomarkers to RCRI scores improved the prediction of 30-day MACE. CONCLUSIONS: This study demonstrates the utility of hs-cTnI and sST2 in predicting 30-day MACE following non-cardiac surgery. Cardiac biomarkers would provide enhanced risk stratification in addition to clinical RCRI scores for patients undergoing major non-cardiac surgery.


Subject(s)
Humans , Biomarkers , Critical Care , Prognosis , Troponin I , Troponin
16.
Laboratory Medicine Online ; : 111-119, 2017.
Article in English | WPRIM | ID: wpr-110642

ABSTRACT

BACKGROUND: JEOL BioMajesty JCA-BM6010/C (JCA-BM6010/C, JEOL Ltd., Japan) is a recently developed ultra-compact automated clinical chemistry analyzer with a throughput of 1,200 tests per hour. Here, we present the first performance evaluation of JCA-BM6010/C. METHODS: We evaluated the precision, linearity, correlation, accuracy, and carryover of 11 analytes (ALP, ALT, AST, calcium, creatinine, GGT, glucose, LDH, total bilirubin, total protein, and uric acid) using the JEOL closed reagent (JEOL Ltd.) according to the guidelines of the Clinical Laboratory Standards Institute. Linearity was further evaluated for ALT, AST, and GGT using open reagents by Sekisui (Japan). The performance of JCA-BM6010/C was compared to that of the Roche-Hitachi Cobas 8000 c702 chemistry autoanalyzer (Cobas 8000, Roche Diagnostics, Switzerland). Its performance using open reagents from Denka Seiken (Japan), Roche, and Sekisui was also evaluated. RESULTS: The total coefficients of variation (CV) for all analytes were 1.0–2.7%. Linearity was observed for all analytes over the entire tested analytical range (R²≥0.99). The results of JCA-BM6010/C strongly correlated (r≥0.988) with those of Cobas 8000 for all evaluated analytes except LDH (r=0.963), as well as for all open reagents. Recovery rates for creatinine, glucose, calcium, and uric acid were 96.6–101.5% and 98.7–109.3% with the JEOL exclusive and open reagents, respectively. Sample carryover was less than 0.34%. CONCLUSIONS: JCA-BM6010/C showed acceptable performance in the precision, linearity, correlation, accuracy, and sample carryover analyses and in the method comparison. Therefore, it could be a useful routine laboratory medical analyzer.


Subject(s)
Bilirubin , Calcium , Chemistry , Chemistry, Clinical , Creatinine , Glucose , Indicators and Reagents , Methods , Uric Acid
17.
Korean Journal of Blood Transfusion ; : 13-27, 2017.
Article in Korean | WPRIM | ID: wpr-34211

ABSTRACT

The primary goal in transfusion medicine is to promote high standards of quality in all aspects of transfusion, including production, management, and transfusion of blood components. To achieve this goal, a transfusion service quality management system should be established. Such a system should include several organizational structures, responsibilities, policies, processes, procedures, and resources with provided specifications and regulations. In this review, we summarize the current knowledge and practices regarding the quality management of hematology tests applied to the donor selection and production of blood components, including red blood cells, platelets, fresh frozen plasma, and cryoprecipitates in the field at blood centers.


Subject(s)
Humans , Donor Selection , Erythrocytes , Hematology , Plasma , Social Control, Formal , Tissue Donors , Transfusion Medicine
18.
Laboratory Medicine Online ; : 176-181, 2017.
Article in Korean | WPRIM | ID: wpr-51172

ABSTRACT

BACKGROUND: Soluble ST2 (sST2) has emerged as a biomarker of heart failure. Previous studies indicated 35 ng/mL of sST2 as the clinically prognostic cut-off value. This study aims to establish reference intervals in a Korean population using an sST2 assay and to evaluate the applicability of the cut-off value. METHODS: From March to May 2014, sST2 levels were assayed in serum samples of 255 cardio-healthy Koreans (128 men and 127 women) using the Presage ST2 ELISA kit (Critical Diagnostics, USA). The reference interval for sST2 was defined using the nonparametric percentile method according to the CLSI EP28-A3c guideline. RESULTS: The median sST2 concentrations were 23.8 ng/mL (interquartile range (IQR), 19.0-28.7), 26.6 ng/mL (IQR, 21.0-30.9), and 21.9 ng/mL (IQR, 17.3-26.5) for the entire cohort, men, and women, respectively. sST2 levels were significantly higher in men than in women (P<0.0001). The 97.5th percentile upper reference limits for sST2 were 43.8 ng/mL, 49.6 ng/mL, and 35.4 ng/mL for the cohort, men, and women, respectively. Gender-specific upper reference limits were similar to limits reported by other studies. CONCLUSIONS: We suggest that gender-specific reference intervals should be used for the Korean population, as application of a single cut-off value of 35 ng/mL may be overcautious of the possibility of false positivity, especially in men.


Subject(s)
Female , Humans , Male , Cohort Studies , Enzyme-Linked Immunosorbent Assay , Heart Failure , Methods
19.
Annals of Laboratory Medicine ; : 34-38, 2017.
Article in English | WPRIM | ID: wpr-72420

ABSTRACT

BACKGROUND: The associations of vitamin D deficiency with various clinical conditions highlighted the importance of vitamin D testing. Currently, clinicians measure only the total 25-hydroxyvitamin D [25(OH)D] concentration, regardless of its bioavailability. We aimed to determine the effect of vitamin D-binding protein (VDBP) on 25(OH)D bioavailability. METHODS: Serum samples were collected from 60 healthy controls, 50 pregnant women, and 50 patients in intensive care units (ICUs). Total 25(OH)D was quantified by liquid chromatography with tandem mass spectrometry, and VDBP levels were determined by using an ELISA kit (R&D Systems, USA). The bioavailable 25(OH)D levels were calculated by using total 25(OH)D, VDBP, and albumin concentrations. RESULTS: In comparison with healthy controls, the total 25(OH)D concentration was significantly lower in ICU patients (median, 11.65 vs 18.25 ng/mL; P<0.00001), but no significant difference was noted between pregnant women (18.25 ng/mL) and healthy controls. The VDBP level was significantly lower in ICU patients (95.58 vs 167.18 µg/mL, P=0.0002) and higher in pregnant women (225.01 vs 167.18 µg/mL, P=0.008) compared with healthy controls. Nonetheless, the calculated bioavailable 25(OH)D levels of ICU patients and pregnant women were significantly lower than those of healthy controls (1.97 and 1.93 ng/mL vs 2.56 ng/mL; P=0.0073 and 0.0027). CONCLUSIONS: A single marker of the total 25(OH)D level is not sufficient to accurately evaluate vitamin D status, especially in pregnant women. In cases where VDBP concentrations may be altered, VDBP measurements and bioavailable 25(OH)D calculations may help to determine vitamin D status accurately.


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Pregnancy , Chromatography, High Pressure Liquid , Enzyme-Linked Immunosorbent Assay , Intensive Care Units , Pregnant Women , Serum Albumin/analysis , Tandem Mass Spectrometry , Vitamin D/blood , Vitamin D-Binding Protein/blood
20.
Annals of Laboratory Medicine ; : 129-136, 2017.
Article in English | WPRIM | ID: wpr-8650

ABSTRACT

BACKGROUND: Cytomegalovirus (CMV) and Epstein-Barr virus (EBV) are increasingly important in immunocompromised patients. Nucleic acid extraction methods could affect the results of viral nucleic acid amplification tests. We compared two automated nucleic acid extraction systems for detecting CMV and EBV using real-time PCR assays. METHODS: One hundred and fifty-three whole blood (WB) samples were tested for CMV detection, and 117 WB samples were tested for EBV detection. Viral nucleic acid was extracted in parallel by using QIAsymphony RGQ and QIAcube (Qiagen GmbH, Germany), and real-time PCR assays for CMV and EBV were performed with a Rotor-Gene Q real-time PCR cycler (Qiagen). Detection rates for CMV and EBV were compared, and agreements between the two systems were analyzed. RESULTS: The detection rate of CMV and EBV differed significantly between the QIAsymphony RGQ and QIAcube systems (CMV, 59.5% [91/153] vs 43.8% [67/153], P=0.0005; EBV, 59.0% [69/117] vs 42.7% [50/117], P=0.0008). The two systems showed moderate agreement for CMV and EBV detection (kappa=0.43 and 0.52, respectively). QIAsymphony RGQ showed a negligible correlation with QIAcube for quantitative EBV detection. QIAcube exhibited EBV PCR inhibition in 23.9% (28/117) of samples. CONCLUSIONS: Automated nucleic acid extraction systems have different performances and significantly affect the detection of viral pathogens. The QIAsymphony RGQ system appears to be superior to the QIAcube system for detecting CMV and EBV. A suitable sample preparation system should be considered for optimized nucleic acid amplification in clinical laboratories.


Subject(s)
Humans , Automation , Cytomegalovirus/genetics , Cytomegalovirus Infections/diagnosis , DNA, Viral/blood , Herpesvirus 4, Human/genetics , Reagent Kits, Diagnostic , Real-Time Polymerase Chain Reaction
SELECTION OF CITATIONS
SEARCH DETAIL